cat da 12t 2008 en Silniki, Instrukcje, SIEMENS KATALOGI, KATALOGI, katalog 1

[ Pobierz całość w formacie PDF ]
© Siemens AG 2008
dc motors
Engineering information
for Catalog DA 12
© Siemens AG 2008
Catalogs for "Large Drives"
SINAMICS G130/G150
Drive Converter Chassis Units
Drive Converter Cabinet Units
Order No.:
German: E86060-K5511-A101-A3
English: E86060-K5511-A101-A3-7600
D 11
SIMOREG DC-MASTER 6RA70
DA 21.1
Digital Chassis Converters
Order No.:
German: E86060-K5321-A111-A2
English: E86060-K5321-A111-A2-7600
www.siemens.com/simoreg-catalog
SINAMICS GM150/SM150
Medium-Voltage Converters
0.8 MVA to 28 MVA
Order No.:
German: E86060-K5512-A101-A1
English: E86060-K5512-A101-A1-7600
D 12
Spare Parts for SIMOREG
DC MASTER 6RA70
DA 21.1 E
www.siemens.de/simoreg-katalog
www.siemens.com/simoreg-catalog
SINAMICS S120
Drive System
0.12 kW to 1200 kW
Order No.:
German: E86060-K5521-A111-A2
English: E86060-K5521-A111-A2-7600
D 21.1
SIMOREG K 6RA22
Analog Chassis Converters
DA 21.2
Order No.:
German: E86060-K5121-A121-A1
English: E86060-K5121-A121-A1-7600
SINAMICS S150
Drive Converter Cabinet Units
75 kW to 1200 kW
Order No.:
German: E86060-K5521-A131-A1
English: E86060-K5521-A131-A1-7600
D 21.3
SIMOREG DC MASTER 6RM70
DA 22
Digital Converter Cabinet Units
www.siemens.de/simoreg-katalog
www.siemens.com/simoreg-catalog
Asynchronous Motors
Standardline
N-compact 1LA8/H-compact 1LA4
Order No.:
German: E86060-K5586-A111-A2
English: E86060-K5586-A111-A2-7600
D 86.1
Catalog CA 01
The Offline Mall of Automation
and Drives
CA 01
Order No.:
German: E86060-D4001-A100-C6 (CD-ROM)
E86060-D4001-A500-C6 (DVD)
English: E86060-D4001-A110-C6-7600 (CD-ROM)
E86060-D4001-A510-C6-7600 (DVD)
Three-phase synchronous
motors
HT-direct 1FW4
Order No.:
German: E86060-K5586-A121-A2
English: E86060-K5586-A121-A2-7600
D 86.2
A&D Mall
Internet:
www.siemens.com/automation/mall
DC Motors
Sizes 160 to 630
31.5 kW to 1610 kW
Order No.:
German: E86060-K5312-A101-A2
English: E86060-K5312-A101-A2-7600
DA 12
SINAMICS MICROMASTER SIZER
Configuration tool
Order No.: 6SL3070-0AA00-0AG0
The configuration of DC-motors and converters is
realized via SIZER LD Snap-in Suite, which has to be
obtained from the regional contact partner and installed
in addition to the SINAMICS MICROMASTER SIZER.
DC Motors
Engineering information
for Catalog DA 12
Order No.:
German: E86060-T5312-A101-A2
English: E86060-T5312-A101-A2-7600
DA 12 T
 © Siemens AG 2008
Engineering informa-
tion for Catalog DA 12
2
Introduction
DC Motors
General technical information
Short code table
General information on the dimension tables in
Catalog DA12
3
5
DA 12 T · 2008
Motor designs
Overview of cooling types and degrees of protection
6
Supersedes:
Engineering information for
Catalog DA 12 · 2005
Mechanical design
Structure of standard DC motors
DURIGNIT 2000 insulation system
Windings, magnetic circuit, current rate of rise and
commutation
7
8
8
© Siemens AG 2007
Electrical data
Supply, converter connection, armature voltage and
smoothing reactor
Speed and speed control
Output and overload capacity
Other operating and ambient conditions
Field
9
10
11
13
13
Mechanical data
Types of construction
Cooling type, degree of protection
Cooling, air flow direction
Air-to-water and air-to-air coolers
Fan units
Filter and silencer mounting
Noise levels
Bearings
Shaft ends
Mechanical performance, vibrations
Te r m i n a l b o x e s
Paint finish
15
16
16
18
18
20
21
21
27
27
28
30
The products and sys-
tems described in this
catalog are manufac-
tured/distributed under
application of a certified
quality management
system in accordance
with EN ISO 9001
(Certified Registration
No. 002241 QM UM).
The certificate is recog-
nized by all IQNet coun-
tries.
Protective and monitoring devices
Thermal motor protection
Earthing brushes
Brush monitoring
Bearing temperature and bearing condition
Air flow monitoring
31
31
31
32
32
Accessories
Anti-condensation heating
Mounted equipment
Installation and mounting of motors
33
33
36
37
Spare parts
37
Documentation
s
Shipping data
Packaging tares for overland and sea transportation
37
38
Subject Index
 © Siemens AG 2008
Engineering information for Catalog DA 12 · DC Motors
Introduction
Siemens DC machines are used wherever power saving tech-
nology and high availability are required. Due to their high output
density with small outside dimensions and their modular installa-
tion, they perfectly fit into even the smallest installation space.
Due to the stepless adjustable speed, the drive can be optimally
adapted to the respective conditions of use.
Together with the digital SIMOREG DC MASTER converter, the
DC drives can be found in all industrial sectors all over the world.
DC technology is used in rolling mills, in paper machines, on
cranes, in extruders, in printing machines, on presses and on
skiing lifts.
Siemens DC machines are available for frame sizes from
160 to 630.
Depending on the frame size, the motors are built in 4 or 6-pole
versions.
Armature voltages of up to 810 V are also possible.
The motors are available with various cooling types, open-circuit
ventilation, or closed-circuit ventilation with degrees of protec-
tion IP23 or IP54.
A vast range of installation and mounting accessories, as well as
protection and monitoring devices round up our supply.
For selection of the motors there are at your disposal
Catalog DA 12 · 2008 or the motor selection tool SINAMICS
MICROMASTER SIZER with LD add ons.
This “Technical Information” may help you to solve additional
problems concerning the configuration and operation of the DC
machine. It contains a mounting description and an accessories
description of the machines and serves as supplement to Cata-
log DA 12 · 2008.
2
Siemens DA 12 T · 2008
 © Siemens AG 2008
Engineering information for Catalog DA 12 · DC Motors
General technical information
Short code table
The following table gives an overview over short codes used for
DC motors.
The use of these short codes, possible restrictions with various
motor versions and frame sizes are described in Catalog
DA 12 · 2008, section “Selection and Ordering – Options”.
Short code table for field voltage with digit “9” at position 11 of
the order number (refer to section “Field”, page 13)
Short code table for order numbers with “-Z” (refer to Catalog
DA 12 · 2008, section “Selection and Ordering – Options”)
Short
Code
Meaning
A00
Brush monitoring, signalling brush
A05
Earthing brushes
A06
Brush monitoring, microswitch
Short
Code
Meaning
A08
Air flow monitor 24 V DC, type 3201.01
A09
Air flow monitor 230 V AC, type 3201.51
L3Y
Non-standard field voltage 110 V – 500 V
A11
PTC thermistor, tripping
L4Y
Non-standard field voltage < 110 V, > 500 V
A12
PTC thermistor, alarm + tripping
L5A
Field voltage 200 V
A23
KTY 84
L5B
Field voltage 350 V
A31
Thermostatic switch, tripping
L5C
Field voltage 190 V
A45
Resistance thermometer in cooling circuit
L5D
Field voltage 325 V
A62
PT100
L5E
Field voltage 340 V
A76
Bearing monitoring with PT 100
L5F
Field voltage 330 V
A97
Air flow monitor 24 V DC type 3201.03
Short code table for the type of construction with digit “9” at
position 12 of the order number (refer to section “Types of con-
struction”, page 15)
C00
Brake 24 V DC
C05
Field weakening speeds 1.15 to 1.7 x
n
N
Short
Code
Meaning
C06
Field weakening speeds > 1.7 x
n
N
C34
1)
Paper machine drives
M1A
Type of construction IM B6
C35
1)
Extruder drives
M1B
Type of construction IM B7
C36
1)
Pump motors for waterworks
M1C
Type of construction IM B8
C37
1)
Press motors
M1D
Type of construction IM V5 w/o protective cover
C38
1)
Motors for lifts and cable railways (up to –20 °C KT)
M1E
Type of construction IM V6
C40
1)
Printing machine drives
M1G
Type of construction IM V3
C41
1)
Rolling mill drives
M1H
Type of construction IM V15
C42
1)
Lifting gear drives
M1J
Type of construction IM V35
C49
Flexible commutator infeed
G00
Fan mounted on the non-drive end left,
air intake from the non-drive end
G01
Fan mounted on the non-drive end left,
air intake from the drive end
G02
Fan mounted on the non-drive end right,
air intake from the non-drive end
G03
Fan mounted on the non-drive end right,
air intake from the drive end
G04
Fan mounted on the non-drive end top,
air intake from the non-drive end
G05
Fan mounted on the non-drive end top,
air intake from the drive end
G06
Fan mounted on the drive end left,
air intake from the non-drive end
G07
Fan mounted on the drive end left,
air intake from the drive end
G08
Fan mounted on the drive end right,
air intake from the non-drive end
G09
Fan mounted on the drive end right,
air intake from the drive end
G10
Fan mounted on the drive end top,
air intake from the non-drive end
G11
Fan mounted on the drive end top,
air intake from the drive end
G14
Air filter
G15
Silencer
1)
The machine design depends on the user-specific operating con-
ditions. The performed measures depend on the frame size and
cooling type of the motor.
3
Siemens DA 12 T · 2008
  [ Pobierz całość w formacie PDF ]

  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • natro.keep.pl
  • Copyright 2016 Lisbeth Salander nienawidzi mężczyzn, którzy nienawidzą kobiet.
    Design: Solitaire