cdc nfa010, Elektronika, Zasilacze i przetwornice AC-DC DC-DC noty katalogowe EDW, Noty zasilacze, Murata Power ...

[ Pobierz całość w formacie PDF ]
Non-Isolated 10A SIP/SMT DC/DC
VOLANT NFA010 SERIES
Features:
9
Small size, minimal footprint – SMT/SIP package
9
10A Output Current (all voltages)
9
High Efficiency: up to 95%
9
High reliability
9
RoHS Compliant
9
Cost efficient open frame design
9
Output voltage programmable by an external resistor.
9
Monotonic Startup with Pre-Bias
9
+’ve Enable Logic and –‘ve Enable Logic models available
9
Optional Power Good Signal
9
Sequencing / Tracking Feature
Output
Input
Efficiency
Vout
(V)
Iout
(A)
PARD
(mVp-p)
Regulation
Max
Vin
Nom.
(V)
Range
(V)
Iin
Typ
(A)
Full Load
Typ. Max.
Line
Load
Typ.
0.75
10
50
75
+/-0.2%
+/-0.5%
12
6.0 – 14
0.8
80%
1.2
10
50
75
+/-0.2%
+/-0.5%
12
6.0 – 14
1.2
86%
1.5
10
50
75
+/-0.2%
+/-0.5%
12
6.0 – 14
1.4
89%
1.8
10
50
75
+/-0.2%
+/-0.5%
12
6.0 – 14
1.7
90%
2.0
10
50
75
+/-0.2%
+/-0.5%
12
6.0 – 14
1.8
91%
2.5
10
50
75
+/-0.2%
+/-0.5%
12
6.0 – 14
2.3
92%
3.3
10
50
75
+/-0.2%
+/-0.5%
12
6.0 – 14
3.0
93%
5.0
10
50
75
+/-0.2%
+/-0.5%
12
6.5 – 14
4.4
95%
Technical enquiries email: sales@murata-ps.com, tel: +508 339 3000
1
NFA010_6200880000_ B01_21/04/08
 Non-Isolated 10A SIP/SMT DC/DC
VOLANT NFA010 SERIES
Murata Power Solutions
Input Characteristics
Notes & Conditions
Min
Typ.
Max
Units
Input Voltage Operating Range
6.0
12
14
Vdc
Minimum 6.5 V input @ 5 volts output
Input Reflected Ripple Current
200
mA p-p
A
2
s
Inrush Current Transient
0.2
Input Filter Type (external)
100
μ
F
Input Turn ON Threshold
5.0
V
Input Turn OFF Threshold
4.0
V
Enable
(Positive enable has 20K pullup)
(Negative enable has no internal
pullup resistor)
Positive enable: ON
open
Positive enable: OFF
<0.4
Vdc
Negative enable: ON;
open circuit or
<0.4
Vdc
Negative enable: OFF
2
Vin
Output Characteristics
Notes & Conditions
Min
Typ.
Max
Units
Vout Accuracy
100% load
-1.5
+1.5
%
Output Loading
0
10
A
Output Ripple & Noise
@ 20Mhz Bandwidth.
75
mVp-p
Maximum Capacitive Load
Low ESR
8000
μ
F
Vout Trim Range (Nom)
0.75
5.0
V
Total Accuracy
Over line/load temperature
<2%
Current Limit
23
A
Output Line Regulation
-0.2
+0.2
%
Output Load Regulation
-0.5
+0.5
%
Turn-on Overshoot
1
%
SC Protection Technique
Hiccup with auto recovery
Pre-bias Start-up at output
Unit starts monotonically with pre-
bias
Dynamic Characteristics
Notes & Conditions
Min
Typ.
Max
Units
Load Transient
100
mV
50% step, 0.1A/
μ
s
Settling Time
200
μ
s
Operating Frequency
300
KHz
Rise Time
10% Vo to 90% Vo
3.5
ms
Start-Up Time
Vin to Vout and On/Off to Vout
Vout rise to monotonic
7
ms
General Specifications
Notes & Conditions
Min
Typ.
Max
Units
MTBF
Calculated (MIL-HDBK-217F)
919.53
KHrs
Thermal Protection
See thermal derating text
110
°C
Operating Ambient Temperature
Without derating 300LFM
-40
50
°C
Operating Ambient Temperature
See Power derating curve
-40
85
°C
SIP Dimensions
2”Lx0.327”Wx0.512”H
(50.8x8.3x13.0mm)
SMT Dimensions
1.30”Lx0.53”Wx0.366”H
(33x13.46x9.3mm)
SIP Pin Dimensions
0.025” (0.64mm) SQUARE
0.64
mm
SMT Block Dimensions
0.063” x0.065” x 0.112” , SQUARE
Pin and Block Material
Matte Sn Finish on component
Leads
Flammability Rating
UL94V-0
2
NFA010_6200880000_ B01_21/04/08
 Non-Isolated 10A SIP/SMT DC/DC
VOLANT NFA010 SERIES
Murata Power Solutions
Standards Compliance
CSA C22.2, No.60950/UL 60950, Third Edition (2000), File UL E165113
Thermal Considerations
The power module operates in a variety of thermal environments; however, sufficient cooling should
be provided to help ensure reliable operation of the unit.
The thermal data presented is based on measurements taken at various airflows. Note that airflow is
parallel to the long axis of the module as shown in Figure 1 and derating applies accordingly.
Figure 1. Thermal Tests Set-Up.
The temperature at either location should not exceed 110
°
C. Over-temperature shutdown is
evaluated at these locations. The output power of the module should not exceed the rated power for
the module(Vo,set X Io,max).
Requirements for Cooling
To predict the approximate cooling needed for the module, refer to the Power Derating Curves in
Figures 2-17 .
These derating curves are approximations of the ambient temperature and airflow required to keep
the power module temperature below it's maximum rating. Once the module is assembled in the
actual system, the module's temperature should be verified.
3
NFA010_6200880000_ B01_21/04/08
 Non-Isolated 10A SIP/SMT DC/DC
VOLANT NFA010 SERIES
Murata Power Solutions
TYPICAL DERATING CURVES SIP/SMT VERSION
SMT10W-12S05A Vo=0.75V Derating Curve
NFA010 SMT Derating Curve Vout=0.75V
12
10
8
6
0LFM
100LFM
200LFM
300LFM
4
2
0
30
40
50
60
70
80
90
Ambient Temperature (C)
Fig. 2. SMT Power Derating vs Output Current for 12Vin 0.75V Out.
NFA010 SIP Derating Curve Vout=0.75V
SIP 10W-12S05A Derating Curve V1.0 Vo ut=0.75V
12
10
8
0LFM
10 0 L F M
200LFM
300LFM
6
4
2
0
30
40
50
60
70
80
90
Ambient Temperature(C)
Fig. 3. SIP Power Derating vs Output Current for 12Vin 0.75V Out.
4
NFA010_6200880000_ B01_21/04/08
Non-Isolated 10A SIP/SMT DC/DC
VOLANT NFA010 SERIES
Murata Power Solutions
NFA010 SMT Derating Curve Vout=1.2V
SMT10W-12S05A Vo=1.2V Derating Curve
12
10
8
6
0LFM
100LFM
200LFM
300LFM
4
2
0
30
40
50
60
70
80
90
Ambient Temperature (C)
Fig 4. SMT Power Derating vs Output Current for 12Vin 1.2V Out.
SIP 10W-12S05A Derating Curve V1.0 Vo ut=1.2V
NFA010 SIP Derating Curve Vout=1.2V
12
10
8
0LFM
100LFM
200LFM
300LFM
6
4
2
0
30
40
50
60
70
80
90
Ambient Temperature(C)
Fig 5. SIP Power Derating vs Output Current for 12Vin 1.2V Out.
5
NFA010_6200880000_ B01_21/04/08
[ Pobierz całość w formacie PDF ]

  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • natro.keep.pl
  • Copyright 2016 Lisbeth Salander nienawidzi mężczyzn, którzy nienawidzą kobiet.