cdc nea016, Elektronika, Zasilacze i przetwornice AC-DC DC-DC noty katalogowe EDW, Noty zasilacze, Murata Power ...

[ Pobierz całość w formacie PDF ]
Volant NEA016 Series
Non-Isolated 16A SIP/SMT DC/DC Converters
Features:
9
Small size, minimal footprint – SMT/SIP package
9
16A Output Current (all voltages)
9
High Efficiency: up to 94%
9
High reliability
9
RoHS Compliant
9
Cost efficient open frame design
9
Output voltage programmable by an external resistor.
9
Monotonic Start with Pre-Bias.
9
+ve Enable Logic and –ve Enable Logic models available
Output
Input
Efficiency
Vout
(V)
Iout
(A)
PARD
(mVp-p)
Regulation
Max
Vin
Nom.
(V)
Range
(V)
Iin
Typ
(A)
Full Load
Typ. Max.
Line
Load
Typ.
0.75
16
50
75
+/-0.2%
+/-0.5%
12
8.3 – 14
1.299
77%
1.2
16
50
75
+/-0.2%
+/-0.5%
12
8.3 – 14
1.928
83%
1.5
16
50
75
+/-0.2%
+/-0.5%
12
8.3 – 14
2.326
86%
1.8
16
50
75
+/-0.2%
+/-0.5%
12
8.3 – 14
2.727
88%
2.0
16
50
75
+/-0.2%
+/-0.5%
12
8.3 – 14
2.996
89%
2.5
16
50
75
+/-0.2%
+/-0.5%
12
8.3 – 14
3.704
90%
3.3
16
50
75
+/-0.2%
+/-0.5%
12
8.3 – 14
4.783
92%
5.0
16
50
75
+/-0.2%
+/-0.5%
12
8.3 – 14
7.092
94%
Technical enquiries email: sales@murata-ps.com, tel: +508 339 3000
1
NEA016_6200860000_B01_21/04/08
 Volant NEA016 Seri
es
Non-Isolated 16A SIP/SMT DC/DC Converters
Murata Power Solutions
Input Characteristics
Notes & Conditions
Min
Typ.
Max
Units
Input Voltage Operating Range
8.3
12
14
Vdc
Input Reflected Ripple Current
200
mA p-p
A
2
s
Inrush Current Transient
0.2
Input Filter Type (external)
100
μ
F
Input Turn ON Threshold
8.5
V
Input Turn OFF Threshold
8.0
V
ON Control
Open Circuit or =Vin
OFF Control
< 0.4Vdc
Output Characteristics
Notes & Conditions
Min
Typ.
Max
Units
Vout Accuracy
100% load
-1.5
+1.5
%
Output Loading
0
16
A
Output Ripple & Noise
@ 20Mhz Bandwidth.
75
MVp-p
Maximum Capacitive Load
Low ESR
8000
μ
F
Vout Trim Range (Nom)
0.75
5.0
V
Total Accuracy
Over line/load temperature
<2%
Current Limit
23
A
Output Line Regulation
-0.2
+0.2
%
Output Load Regulation
-0.5
+0.5
%
Turn-on Overshoot
1
%
SC Protection Technique
Hiccup with auto recovery
Pre-bias Start-up at output
Unit starts monotonically with pre-
bias
Dynamic Characteristics
Notes & Conditions
Min
Typ.
Max
Units
Load Transient
100
mV
50% step, 0.1A/
μ
s
Settling Time
200
μ
s
Frequency
300
KHz
Rise Time
10% Vo to 90% Vo
3.5
ms
Start-Up Time
Vin to Vout and On/Off to Vout
Vout rise to monotonic
7
ms
General Specifications
Notes & Conditions
Min
Typ.
Max
Units
x10
6
Hrs
x10
6
Hrs
MTBF
Calculated (MIL-HDBK-217F)
Calculated (Bellcore TR-332, Issue 6)
1.0
4.78
Thermal Protection
Hotspot
110
°C
Operating Temperature
Without derating 300LFM
-40
50
°C
Operating Ambient Temperature
See Power derating curve
-40
85
°C
SIP Dimensions
2”Lx0.327”Wx0.512”H
(50.8x8.3x13.0mm)
SMT Dimensions
1.30”Lx0.53”Wx0.366”H
(33x13.46x9.3mm)
SIP Pin Dimensions
0.025” (0.64mm) SQUARE
0.64
mm
SMT Block Dimensions
0.063” x0.065” x 0.112”
SQUARE
Pin and Block Material
Matte Sn Finish on component Leads
Weight
10
g
Flammability Rating
UL94V-0
2
NEA016_6200860000_B01_21/04/08
 Volant NEA016 Seri
es
Non-Isolated 16A SIP/SMT DC/DC Converters
Murata Power Solutions
Standards Compliance
CSA C22.2, No.60950/UL 60950, Third Edition (2000), File UL E165113
Thermal Considerations
The power module operates in a variety of thermal environments; however, sufficient cooling should
be provided to help ensure reliable operation of the unit.
The thermal data presented is based on measurements taken at various airflows. Note that airflow is
parallel to the long axis of the module as shown in Figure 1 and derating applies accordingly.
Figure 1. Thermal Tests Set-Up.
The temperature at either location should not exceed 110
°
C. The output power of the module should
not exceed the rated power for the module(Vo,set X Io,max).
Convection Requirements for Cooling
To predict the approximate cooling needed for the module, refer to the Power Derating Curves in
Figures 2-17 .
These derating curve are approximations of the ambient temperature and airflow required to keep the
power module temperature below it's maximum rating. Once the module is assembled in the actual
system, the module's temperature should be verified.
3
NEA016_6200860000_B01_21/04/08
 Volant NEA016 Seri
es
Non-Isolated 16A SIP/SMT DC/DC Converters
Murata Power Solutions
TYPICAL DERATING CURVES SIP/SMT VERSION
NEA0161501S Vo=0.75V Derating Curve
18
16
14
12
10
0LFM
100LFM
200LFM
300LFM
8
6
4
2
0
20
30
40
50
60
70
80
90
100
Ambient Temperature(C)
Fig. 2. SMT Power Derating vs Output Current for 12Vin 0.75V Out.
NEA0161501B Vo=0.75V Derating Curve
18
16
14
12
10
0LFM
100LFM
200LFM
300LFM
8
6
4
2
0
20
30
40
50
60
70
80
90
100
Ambient Temperature(C)
Fig. 3. SIP Power Derating vs Output Current for 12Vin 0.75V Out.
4
NEA016_6200860000_B01_21/04/08
 Volant NEA016 Seri
es
Non-Isolated 16A SIP/SMT DC/DC Converters
Murata Power Solutions
NEA0161501S Vo=1.2V Derating Curve
18
16
14
12
10
0LFM
100LFM
200LFM
300LFM
8
6
4
2
0
20
30
40
50
60
70
80
90
100
Ambient Temperature(C)
Fig 4. SMT Power Derating vs Output Current for 12Vin 1.2V Out.
NEA0161501B Vo=1.2V Derating Curve
18
16
14
12
10
0LFM
100LFM
200LFM
300LFM
8
6
4
2
0
20
30
40
50
60
70
80
90
100
Ambient Temperature(C)
Fig 5. SIP Power Derating vs Output Current for 12Vin 1.2V Out.
5
NEA016_6200860000_B01_21/04/08
  [ Pobierz całość w formacie PDF ]

  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • natro.keep.pl
  • Copyright 2016 Lisbeth Salander nienawidzi mężczyzn, którzy nienawidzą kobiet.
    Design: Solitaire